Belzona® Reseals Skylight Frames On Administration Building

TitleDetails
IndustryOil & Gas
ApplicationBuilding and Structures – Roof Problem Area
Application DateApril 2013
Application SituationAdmin Building Skylight Glazing Bars require resealing
ProblemDeterioration of the existing mastic sealant in the roof glazing bars had resulted in water leakage into the Admin Building below
ProductsBelzona 2211 Belzona 2921 Belzona 3111 Belzona 3921 Belzona 9311
SubstrateSteel / Glass
Application MethodThe stainless steel cladding section was removed to expose the steel glazing bar. This was cleaned and prepared to remove any corrosion damage. A fillet of Belzona 2211 was applied on to the conditioned surface around the glazing bar / glass panel interface to seal the edge. Following this the stainless steel cladding was replaced and the whole sections covered with Belzona 3111 Flexible Membrane System in accordance with Belzona Know-How System Leaflet RPA-3
Belzona Facts (Cost Savings?, Alternatives?, Why Belzona?, etc.)Customer was looking to apply a long term solution that didn’t involve removal of the glass panels to re-establish the seal. Belzona proved to be the ideal solution for the customer
Preparation & Set-Up Ongoing
Preparation & Set-Up Ongoing
Application of Belzona 3111 Ongoing
Application of Belzona 3111 Ongoing
View of the completed application including Belzona 3111 waterproofing protection
View of the completed application including Belzona 3111 waterproofing protection
Completed Application
Completed Application